CONTACT Menu
Close
ABOUT US
PRODUCT
INDUSTRIES
RESOURCES
CONTACT US

PHONE
+1 407.337.0110

INFO
hello@redmeters.com

ADDRESS
6520 Pinecastle Blvd
Orlando, FL USA


MINING

THE CHALLENGE

Traditional techniques of monitoring slurries in the mining process through nuclear and coriolis meters often come with its setbacks. Some of the posing problems that arise with typical density meters are inaccurate data readings, hazardous waste, and tedious regulations resulting in an inefficient process.

THE OPPORTUNITY

With little maintenance and easy in-line installation, the obstacles of inaccurate data readings, nuclear emissions, and tedious regulations are non-factors with the Red Meter. The implementation of our non-nuclear density meter is not only a more safe and viable alternative, but also a comprehensive, actionable solution for the mining process by providing rapid and exact density measurement of slurries.

THE CHALLENGE

Traditional techniques of monitoring slurries in the mining process through nuclear and coriolis meters often come with its setbacks. Some of the posing problems that arise with typical density meters are inaccurate data readings, hazardous waste, and tedious regulations resulting in an inefficient process.

THE OPPORTUNITY

With little maintenance and easy in-line installation, the obstacles of inaccurate data readings, nuclear emissions, and tedious regulations are non-factors with the Red Meter. The implementation of our non-nuclear density meter is not only a more safe and viable alternative, but also a comprehensive, actionable solution for the mining process by providing rapid and exact density measurement of slurries.

INDUSTRY FLOW CHART

TECHNICAL SPECIFICATIONS

RM Series

ACCURACY

Overall: ± 0.25% of reading over 6:1 density range
Digital Response Time: 50ms
Measurement Time: 20 per second
Internal Diameters: 2" - 60" (50 -1524 mm)
Repeatability: ± 0.1% of full scale
Linearity: ± 0.018% of full scale
Pressure Coefficient: 0.1% / psi of full scale
Slurry Temperature Coefficient: ±.3% / 10°C of full scale
Calibration Standards: NIST, OIML, ASTM
RM Series

OPERATIONAL MAXIMUMS

Maximum Working Temperature: 150°F (65°C)
Maximum Pressure: Up to 600 psi (40 bar)
[Safety Factor of 3]
RM Series

INTEGRATION

Flanged Connections: ASTM, DIN, or BS
Environmental Protection: IP66/NEMA 4X
Housing: Powder-Coated Aluminum Shell
Insulation: Hi-Temp Fiberglass, ASTM Compliant
Pipe Supports: Carbon Steel, 5/8" (16mm) bolts
Gaskets: ASTM Compliant
Wiring: IFC Standards
RM Series

FEATURES

Internal Laser Source: Class 2 (FDA (CDRH) Part 1040.10)
Ambient Sensor Sampling: 50 readings per second
Storage Temperature: -40° to 175°F (-40° to 80°C)

GET IN
CONTACT WITH
RED METERS

yes no
* Required Field

GLOBAL SUPPORT

CONTACT US

+1 407.337.0110

6520 PINECASTLE BLVD
ORLANDO, FL USA
FOR INQUIRIES:
HELLO@REDMETERS.COM

CAREERS
CONTACT